- ATEX thermometers
- temperature sensor with connection cable
- flameproof encapsulated temperature sensors
- built-in temperature sensor with connection head or plug
- high temperature thermocouples
- mineral insulated metal sheated thermocouples and resistance thermometers
- measuring inserts
- groove thermometer
- temperature sensor in encapsulation
temperature sensor with connection cable
Temperature sensor for measuring the temperature of process media and components with connection cable for connecting, plugging in or screwing into the corresponding measuring points.
Measuring range:
- -40...+200°C (depending on the cable insulation used)
- shielded and unshielded connection cables as well as
- selection of different insulation materials depending on the area of application
Measuring tip:
- from Ø2,5mm
individual choice:
- of process connections for the respective installation conditions
Connection types:
- free cable ends, connectors, terminal box with/without transmitter
Special designs:
- cable resistance thermometer with oil barrier for determining temperatures in pressure-loaded systems with oily medium (max. pressure 10bar); whereby there is a tensionable passage point for the thermometer into the media space. Instead of the oily medium, pressure- and dust-loaded measuring media are also possible.
- combination with VA corrugated hose or spiral hose
- additional protection tubes and angled designs
- temperature sensor in type of protection increased safety "e" and protection by housing "tb" for temperature detection of process media and components with low and medium temperature loads
Explosion protection (gas and dust atmospheres):
- intrinsic safety, increased safety
- zone 0 and 1
Classifications:
Ex II 1G Ex ia IIC T6-T1 Ga (IECEx und ATEX)
Ex II 1G Ex ia IIIC TX Da (IECEx und ATEX)
Ex II 2G Ex ib IIC T6 Gb (ATEX.
Ex II 2D Ex ib IIIC Tx IP 6X Db (ATEX).
Ex II 2G Ex e IIC T6 Gb (ATEX)
Ex II 2D Ex tb IIIC T80°C IP65 Db (ATEX)
products
VA01c550
Magnetic contact thermometer with spring-loaded sensor tip and shielded connecting cable
VA64.1c54
Contact resistance thermometer in Ex-version (intrinsically safe), with unshielded connecting cable
VA64.1c542o543
VA 64.1c550
Contact resistance thermometer in Ex-version (intrinsically safe), with shielded connection cable
VE30.9c550
Screw-in resistance thermometer in Ex version (intrinsically safe), with silicone connecting cable
VE30.9c551
Screw-in resistance thermometer in Ex-version (intrinsically safe), with shielded connection cable and M12 connector
VK63.6c540
Cable resistance thermometer in Ex version (intrinsically safe), with silicone connecting cable
VK63.6c542 und …543
Cable resistance thermometer in Ex-version (intrinsically safe), with unshielded silicone connecting cable to the aluminium connection housing (delivery with or without transmitter)
VK63.6c550
Cable resistance thermometer in Ex version (intrinsically safe), with shielded connecting cable
VK66.0c550
Cable resistance thermometer in Ex version (intrinsically safe), with shielded connecting cable
VK69.3,2c561
Cable resistance thermometer in Ex-design (intrinsically safe), with straight protection sleeve made of stainless steel, shielded connection cable with Lemosa plug connection as well as cable extension with oil barrier and free ends
VK69…c554
Cable resistance thermometer with oil barrier, straight stainless steel protective sleeve
VK69c564
Cable resistance thermometer with oil barrier, spiral tube and straight stainless steel protective sleeve
VO30.9c…13
Resistance thermometer with thermowell in Ex-design (intrinsically safe), with or without transmitter in aluminium connection housing
VR50.9c…14
External wall resistance thermometer in Ex-version (intrinsically safe) with or without transmitter in aluminium connection housing